Proper moisture testing can prevent job failures

HomeColumnProper moisture testing can prevent job failures

February 17/24, 2020: Volume 35, Issue 17

By Ron Loffredo- Excess moisture is the No. 1 culprit of catastrophic flooring failures in North America. This is often due to condensed construction schedules, fast-tracked projects on land with poor drainage, increased environmental regulations and new flooring materials. What’s more, failure to use proper moisture mitigation solutions can be costly and time consuming.

Typically, moisture affects flooring installations through excess moisture vapor transmission (MVT). This excess MVT becomes trapped between the impervious floor coverings and the concrete slab as it moves upward toward the atmosphere. Moisture can be present as rain or groundwater before the slab is first poured. In addition, the new slab contains water, which is needed for the chemical cure. The time to cure can take up to 30 days, which is unrealistic for today’s construction schedules.

Moisture can also be present in older concrete if the slab was never properly protected. It is always best to test for moisture levels; it should not be assumed an adequate vapor barrier is in place. In a remodel, for example, it’s not always apparent that there may be a moisture problem by looking at the existing flooring.

Elevated moisture levels can also lead to the development of mold and mildew. This can compromise air quality in the building and could break down the adhesives, causing warping and buckling. Excessive moisture vapor can also cause debonding, peaking and other issues.

Testing for moisture by following ASTM F2170 is always recommended. Because moisture typically migrates upward from within the slab, measuring moisture at its surface will not accurately portray the subfloor’s RH. Probes placed at specified depths inside the slab more exactly measure its RH levels and more reliably measure the risk moisture poses to an installation. Be sure to follow the instructions supplied with your RH equipment, the ASTM test method and always refer to the flooring manufacturer’s guidelines for their recommended RH levels.

Also keep in mind that moisture test results will indicate the moisture condition of the slab only at the time of the test. To that end, it is important to measure the moisture as close to the flooring installation date as possible. In addition, the building should represent the actual service condition of the finished floor during testing.

If testing proves excess moisture vapor is present, the next step is to select the right solution. When it comes to preventing moisture, it is important to remember not all moisture mitigation products are created equal. There are many types of products on the market, such as: epoxies, which can be effective up to 100% RH and MVER from 25 lbs; single-component polymers, which can be effective up to 100% RH and MVER 25 lbs; moisture vapor retarders, which are either semi-permeable or semi-impermeable; and plastic membranes, rolled moisture barrier systems that can be effective in 95%–99.5% RH.

 

Ron Loffredo is a senior technical advisor for H.B. Fuller Construction Products. A 35-year industry veteran, he specializes in training and consulting for challenging flooring installation projects.

Must Read

NTCA announces 2024 Tom Ade Scholarship winners

Jackson, Miss.—In a testament to the enduring commitment to supporting the educational aspirations of its members' families, the National Tile Contractors Association (NTCA) announced...

AHF relaunches Armstrong’s MedinPure PVC-free sheet

Mountville, Pa.—AHF Products has relaunched Armstrong Flooring’s MedinPure, a PVC-free homogeneous sheet flooring solution with Diamond 10 technology with Enhanced Traction in 20 new...

Reid Kubesh appointed to NSI board of directors

Oberlin, Ohio—The Natural Stone Institute board of directors has appointed Reid Kubesh (Coldspring) to fill a vacancy left by Alexandra Niedbalski, who resigned her...

Tuesday Tips: Why a sales presentation is not a debate

https://youtu.be/umzVE8HMclI Dalton—The World Floor Covering Association (WFCA) released a new “Tuesday Tips” this week. In the series, WFCA experts presents short video tips for improving customer...

Decora SPC now features Välinge 5G Cross technology

Sweden—Decora, a leading European manufacturing company producing technologically advanced flooring products for an international market, now features Välinge 5G Cross technology on its SPC...

Housing starts fall on interest rate, financing concerns

Washington, D.C.—Housing starts fell in March with interest rates somewhat higher than expected last month as the latest inflation readings failed to show improvement....
Some text some message..
X